<?xml version="1.0" encoding="UTF-8"?><xml><records><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Hill, N Jeremy</style></author><author><style face="normal" font="default" size="100%">Gupta, Disha</style></author><author><style face="normal" font="default" size="100%">Eftekhar, Amir</style></author><author><style face="normal" font="default" size="100%">Brangaccio, Jodi A</style></author><author><style face="normal" font="default" size="100%">Norton, James J S</style></author><author><style face="normal" font="default" size="100%">McLeod, Michelle</style></author><author><style face="normal" font="default" size="100%">Fake, Tim</style></author><author><style face="normal" font="default" size="100%">Wolpaw, Jonathan R</style></author><author><style face="normal" font="default" size="100%">Thompson, Aiko K</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">The Evoked Potential Operant Conditioning System (EPOCS): A Research Tool and an Emerging Therapy for Chronic Neuromuscular Disorders.</style></title><secondary-title><style face="normal" font="default" size="100%">J Vis Exp</style></secondary-title><alt-title><style face="normal" font="default" size="100%">J Vis Exp</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Chronic Disease</style></keyword><keyword><style  face="normal" font="default" size="100%">Conditioning, Operant</style></keyword><keyword><style  face="normal" font="default" size="100%">Electromyography</style></keyword><keyword><style  face="normal" font="default" size="100%">Evoked Potentials</style></keyword><keyword><style  face="normal" font="default" size="100%">H-Reflex</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Neuromuscular Diseases</style></keyword><keyword><style  face="normal" font="default" size="100%">Spinal Cord Injuries</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2022</style></year><pub-dates><date><style  face="normal" font="default" size="100%">2022 08 25</style></date></pub-dates></dates><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;The Evoked Potential Operant Conditioning System (EPOCS) is a software tool that implements protocols for operantly conditioning stimulus-triggered muscle responses in people with neuromuscular disorders, which in turn can improve sensorimotor function when applied appropriately. EPOCS monitors the state of specific target muscles-e.g., from surface electromyography (EMG) while standing, or from gait cycle measurements while walking on a treadmill-and automatically triggers calibrated stimulation when pre-defined conditions are met. It provides two forms of feedback that enable a person to learn to modulate the targeted pathway's excitability. First, it continuously monitors ongoing EMG activity in the target muscle, guiding the person to produce a consistent level of activity suitable for conditioning. Second, it provides immediate feedback of the response size following each stimulation and indicates whether it has reached the target value. To illustrate its use, this article describes a protocol through which a person can learn to decrease the size of the Hoffmann reflex-the electrically-elicited analog of the spinal stretch reflex-in the soleus muscle. Down-conditioning this pathway's excitability can improve walking in people with spastic gait due to incomplete spinal cord injury. The article demonstrates how to set up the equipment; how to place stimulating and recording electrodes; and how to use the free software to optimize electrode placement, measure the recruitment curve of direct motor and reflex responses, measure the response without operant conditioning, condition the reflex, and analyze the resulting data. It illustrates how the reflex changes over multiple sessions and how walking improves. It also discusses how the system can be applied to other kinds of evoked responses and to other kinds of stimulation, e.g., motor evoked potentials to transcranial magnetic stimulation; how it can address various clinical problems; and how it can support research studies of sensorimotor function in health and disease.&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">186</style></issue></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Benjamin Blankertz</style></author><author><style face="normal" font="default" size="100%">Müller, Klaus-Robert</style></author><author><style face="normal" font="default" size="100%">Krusienski, Dean J</style></author><author><style face="normal" font="default" size="100%">Gerwin Schalk</style></author><author><style face="normal" font="default" size="100%">Jonathan Wolpaw</style></author><author><style face="normal" font="default" size="100%">Schlögl, Alois</style></author><author><style face="normal" font="default" size="100%">Pfurtscheller, Gert</style></author><author><style face="normal" font="default" size="100%">Millán, José del R</style></author><author><style face="normal" font="default" size="100%">Schröder, Michael</style></author><author><style face="normal" font="default" size="100%">Niels Birbaumer</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">The BCI competition III: Validating alternative approaches to actual BCI problems.</style></title><secondary-title><style face="normal" font="default" size="100%">IEEE Trans Neural Syst Rehabil Eng</style></secondary-title><alt-title><style face="normal" font="default" size="100%">IEEE Trans Neural Syst Rehabil Eng</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Algorithms</style></keyword><keyword><style  face="normal" font="default" size="100%">Brain</style></keyword><keyword><style  face="normal" font="default" size="100%">Communication Aids for Disabled</style></keyword><keyword><style  face="normal" font="default" size="100%">Databases, Factual</style></keyword><keyword><style  face="normal" font="default" size="100%">Electroencephalography</style></keyword><keyword><style  face="normal" font="default" size="100%">Evoked Potentials</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Neuromuscular Diseases</style></keyword><keyword><style  face="normal" font="default" size="100%">Software Validation</style></keyword><keyword><style  face="normal" font="default" size="100%">Technology Assessment, Biomedical</style></keyword><keyword><style  face="normal" font="default" size="100%">User-Computer Interface</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2006</style></year><pub-dates><date><style  face="normal" font="default" size="100%">06/2006</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/16792282</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">14</style></volume><pages><style face="normal" font="default" size="100%">153-9</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;A&amp;nbsp;&lt;/span&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;brain-computer interface&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;&amp;nbsp;(BCI) is a system that allows its users to control external devices with&amp;nbsp;&lt;/span&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;brain&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;activity. Although the proof-of-concept was given decades ago, the reliable translation of user intent into device control commands is still a major challenge. Success requires the effective interaction of two adaptive controllers: the user's&amp;nbsp;&lt;/span&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;brain&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;, which produces&amp;nbsp;&lt;/span&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;brain&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;&amp;nbsp;activity that encodes intent, and the BCI system, which translates that activity into device control commands. In order to facilitate this interaction, many laboratories are exploring a variety of signal analysis techniques to improve the adaptation of the BCI system to the user. In the literature, many machine learning and pattern classification algorithms have been reported to give impressive results when applied to BCI data in offline analyses. However, it is more difficult to evaluate their relative value for actual&amp;nbsp;&lt;/span&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;online&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;&amp;nbsp;use. BCI data competitions have been organized to provide objective formal evaluations of alternative methods. Prompted by the great interest in the first two BCI Competitions, we organized the third BCI Competition to address several of the most difficult and important analysis problems in BCI research. The paper describes the data sets that were provided to the competitors and gives an overview of the results.&lt;/span&gt;&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">2</style></issue></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Cincotti, F</style></author><author><style face="normal" font="default" size="100%">Bianchi, L</style></author><author><style face="normal" font="default" size="100%">Birch, Gary</style></author><author><style face="normal" font="default" size="100%">Guger, C</style></author><author><style face="normal" font="default" size="100%">Mellinger, Jürgen</style></author><author><style face="normal" font="default" size="100%">Scherer, Reinhold</style></author><author><style face="normal" font="default" size="100%">Schmidt, Robert N</style></author><author><style face="normal" font="default" size="100%">Yáñez Suárez, Oscar</style></author><author><style face="normal" font="default" size="100%">Gerwin Schalk</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">BCI meeting 2005 - Workshop on Technology: Hardware and Software.</style></title><secondary-title><style face="normal" font="default" size="100%">IEEE Trans Neural Syst Rehabil Eng</style></secondary-title><alt-title><style face="normal" font="default" size="100%">IEEE Trans Neural Syst Rehabil Eng</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Algorithms</style></keyword><keyword><style  face="normal" font="default" size="100%">Biotechnology</style></keyword><keyword><style  face="normal" font="default" size="100%">Brain</style></keyword><keyword><style  face="normal" font="default" size="100%">Communication Aids for Disabled</style></keyword><keyword><style  face="normal" font="default" size="100%">Computers</style></keyword><keyword><style  face="normal" font="default" size="100%">Electroencephalography</style></keyword><keyword><style  face="normal" font="default" size="100%">Equipment Design</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Internationality</style></keyword><keyword><style  face="normal" font="default" size="100%">Man-Machine Systems</style></keyword><keyword><style  face="normal" font="default" size="100%">Neuromuscular Diseases</style></keyword><keyword><style  face="normal" font="default" size="100%">Software</style></keyword><keyword><style  face="normal" font="default" size="100%">User-Computer Interface</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2006</style></year><pub-dates><date><style  face="normal" font="default" size="100%">06/2006</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/16792276</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">14</style></volume><pages><style face="normal" font="default" size="100%">128-31</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;This paper describes the outcome of discussions held during the Third International BCI Meeting at a workshop to review and evaluate the current state of BCI-related hardware and software. Technical requirements and current technologies, standardization procedures and future trends are covered. The main conclusion was recognition of the need to focus technical requirements on the users' needs and the need for consistent standards in BCI research.&lt;/span&gt;&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">2</style></issue></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Adam J Wilson</style></author><author><style face="normal" font="default" size="100%">Felton, Elizabeth A</style></author><author><style face="normal" font="default" size="100%">Garell, P Charles</style></author><author><style face="normal" font="default" size="100%">Gerwin Schalk</style></author><author><style face="normal" font="default" size="100%">Williams, Justin C</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">ECoG factors underlying multimodal control of a brain-computer interface.</style></title><secondary-title><style face="normal" font="default" size="100%">IEEE Trans Neural Syst Rehabil Eng</style></secondary-title><alt-title><style face="normal" font="default" size="100%">IEEE Trans Neural Syst Rehabil Eng</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Adult</style></keyword><keyword><style  face="normal" font="default" size="100%">Brain Mapping</style></keyword><keyword><style  face="normal" font="default" size="100%">Cerebral Cortex</style></keyword><keyword><style  face="normal" font="default" size="100%">Communication Aids for Disabled</style></keyword><keyword><style  face="normal" font="default" size="100%">Computer Peripherals</style></keyword><keyword><style  face="normal" font="default" size="100%">Evoked Potentials</style></keyword><keyword><style  face="normal" font="default" size="100%">Female</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Imagination</style></keyword><keyword><style  face="normal" font="default" size="100%">Male</style></keyword><keyword><style  face="normal" font="default" size="100%">Man-Machine Systems</style></keyword><keyword><style  face="normal" font="default" size="100%">Neuromuscular Diseases</style></keyword><keyword><style  face="normal" font="default" size="100%">Systems Integration</style></keyword><keyword><style  face="normal" font="default" size="100%">User-Computer Interface</style></keyword><keyword><style  face="normal" font="default" size="100%">Volition</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2006</style></year><pub-dates><date><style  face="normal" font="default" size="100%">06/2006</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/16792305</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">14</style></volume><pages><style face="normal" font="default" size="100%">246-50</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;Most current brain-computer interface (BCI) systems for humans use electroencephalographic activity recorded from the scalp, and may be limited in many ways. Electrocorticography (ECoG) is believed to be a minimally-invasive alternative to electroencephalogram (&lt;/span&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;EEG&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;) for BCI systems, yielding superior signal characteristics that could allow rapid user training and faster communication rates. In addition, our preliminary results suggest that brain regions other than the sensorimotor cortex, such as auditory cortex, may be trained to control a BCI system using similar methods as those used to train motor regions of the brain. This could prove to be vital for users who have neurological disease, head trauma, or other conditions precluding the use of sensorimotor cortex for BCI control.&lt;/span&gt;&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">2</style></issue></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Theresa M Vaughan</style></author><author><style face="normal" font="default" size="100%">Dennis J. McFarland</style></author><author><style face="normal" font="default" size="100%">Gerwin Schalk</style></author><author><style face="normal" font="default" size="100%">Sarnacki, William A</style></author><author><style face="normal" font="default" size="100%">Krusienski, Dean J</style></author><author><style face="normal" font="default" size="100%">Sellers, Eric W</style></author><author><style face="normal" font="default" size="100%">Jonathan Wolpaw</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">The Wadsworth BCI Research and Development Program: At Home with BCI.</style></title><secondary-title><style face="normal" font="default" size="100%">IEEE Trans Neural Syst Rehabil Eng</style></secondary-title><alt-title><style face="normal" font="default" size="100%">IEEE Trans Neural Syst Rehabil Eng</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Animals</style></keyword><keyword><style  face="normal" font="default" size="100%">Brain</style></keyword><keyword><style  face="normal" font="default" size="100%">Electroencephalography</style></keyword><keyword><style  face="normal" font="default" size="100%">Evoked Potentials</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Neuromuscular Diseases</style></keyword><keyword><style  face="normal" font="default" size="100%">New York</style></keyword><keyword><style  face="normal" font="default" size="100%">Research</style></keyword><keyword><style  face="normal" font="default" size="100%">Switzerland</style></keyword><keyword><style  face="normal" font="default" size="100%">Therapy, Computer-Assisted</style></keyword><keyword><style  face="normal" font="default" size="100%">Universities</style></keyword><keyword><style  face="normal" font="default" size="100%">User-Computer Interface</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2006</style></year><pub-dates><date><style  face="normal" font="default" size="100%">06/2006</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/16792301</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">14</style></volume><pages><style face="normal" font="default" size="100%">229-33</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;The ultimate goal of brain-computer interface (BCI) technology is to provide communication and control capacities to people with severe motor disabilities. BCI research at the Wadsworth Center focuses primarily on noninvasive,&amp;nbsp;&lt;/span&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;electroencephalography&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;&amp;nbsp;(&lt;/span&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;EEG&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;)-based BCI methods. We have shown that people, including those with severe motor disabilities, can learn to use sensorimotor rhythms (SMRs) to move a cursor rapidly and accurately in one or two dimensions. We have also improved P300-based BCI operation. We are now translating this laboratory-proven BCI technology into a system that can be used by severely disabled people in their homes with minimal ongoing technical oversight. To accomplish this, we have: improved our general-purpose BCI software (BCI2000); improved online adaptation and feature translation for SMR-based BCI operation; improved the accuracy and bandwidth of P300-based BCI operation; reduced the&amp;nbsp;&lt;/span&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;complexity&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;&amp;nbsp;of system hardware and software and begun to evaluate home system use in appropriate users. These developments have resulted in prototype systems for every day use in people's homes.&lt;/span&gt;&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">2</style></issue></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Jonathan Wolpaw</style></author><author><style face="normal" font="default" size="100%">Niels Birbaumer</style></author><author><style face="normal" font="default" size="100%">Heetderks, W J</style></author><author><style face="normal" font="default" size="100%">Dennis J. McFarland</style></author><author><style face="normal" font="default" size="100%">Peckham, P H</style></author><author><style face="normal" font="default" size="100%">Gerwin Schalk</style></author><author><style face="normal" font="default" size="100%">Emanuel Donchin</style></author><author><style face="normal" font="default" size="100%">Quatrano, L A</style></author><author><style face="normal" font="default" size="100%">Robinson, C J</style></author><author><style face="normal" font="default" size="100%">Theresa M Vaughan</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Brain-computer interface technology: a review of the first international meeting.</style></title><secondary-title><style face="normal" font="default" size="100%">IEEE Trans Rehabil Eng</style></secondary-title><alt-title><style face="normal" font="default" size="100%">IEEE Trans Rehabil Eng</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Algorithms</style></keyword><keyword><style  face="normal" font="default" size="100%">Cerebral Cortex</style></keyword><keyword><style  face="normal" font="default" size="100%">Communication Aids for Disabled</style></keyword><keyword><style  face="normal" font="default" size="100%">Disabled Persons</style></keyword><keyword><style  face="normal" font="default" size="100%">Electroencephalography</style></keyword><keyword><style  face="normal" font="default" size="100%">Evoked Potentials</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Neuromuscular Diseases</style></keyword><keyword><style  face="normal" font="default" size="100%">Signal Processing, Computer-Assisted</style></keyword><keyword><style  face="normal" font="default" size="100%">User-Computer Interface</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2000</style></year><pub-dates><date><style  face="normal" font="default" size="100%">06/2000</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/10896178</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">8</style></volume><pages><style face="normal" font="default" size="100%">164-73</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;Over the past decade, many laboratories have begun to explore brain-computer interface (BCI) technology as a radically new communication option for those with neuromuscular impairments that prevent them from using conventional augmentative communication methods. BCI's provide these users with communication channels that do not depend on peripheral nerves and muscles. This article summarizes the first international meeting devoted to BCI research and development. Current BCI's use electroencephalographic (EEG) activity recorded at the scalp or single-unit activity recorded from within cortex to control cursor movement, select letters or icons, or operate a neuroprosthesis. The central element in each BCI is a translation algorithm that converts electrophysiological input from the user into output that controls external devices. BCI operation depends on effective interaction between two adaptive controllers, the user who encodes his or her commands in the electrophysiological input provided to the BCI, and the BCI which recognizes the commands contained in the input and expresses them in device control. Current BCI's have maximum information transfer rates of 5-25 b/min. Achievement of greater speed and accuracy depends on improvements in signal processing, translation algorithms, and user training. These improvements depend on increased interdisciplinary cooperation between neuroscientists, engineers, computer programmers, psychologists, and rehabilitation specialists, and on adoption and widespread application of objective methods for evaluating alternative methods. The practical use of BCI technology depends on the development of appropriate applications, identification of appropriate user groups, and careful attention to the needs and desires of individual users. BCI research and development will also benefit from greater emphasis on peer-reviewed publications, and from adoption of standard venues for presentations and discussion.&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">2</style></issue></record></records></xml>