<?xml version="1.0" encoding="UTF-8"?><xml><records><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Cho, Hohyun</style></author><author><style face="normal" font="default" size="100%">Adamek, Markus</style></author><author><style face="normal" font="default" size="100%">Willie, Jon T</style></author><author><style face="normal" font="default" size="100%">Brunner, Peter</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Novel cyclic homogeneous oscillation detection method for high accuracy and specific characterization of neural dynamics.</style></title><secondary-title><style face="normal" font="default" size="100%">Elife</style></secondary-title><alt-title><style face="normal" font="default" size="100%">Elife</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Brain</style></keyword><keyword><style  face="normal" font="default" size="100%">Electrocorticography</style></keyword><keyword><style  face="normal" font="default" size="100%">Electroencephalography</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Signal Processing, Computer-Assisted</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2024</style></year><pub-dates><date><style  face="normal" font="default" size="100%">2024 Sep 06</style></date></pub-dates></dates><volume><style face="normal" font="default" size="100%">12</style></volume><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;Determining the presence and frequency of neural oscillations is essential to understanding dynamic brain function. Traditional methods that detect peaks over 1/ noise within the power spectrum fail to distinguish between the fundamental frequency and harmonics of often highly non-sinusoidal neural oscillations. To overcome this limitation, we define fundamental criteria that characterize neural oscillations and introduce the cyclic homogeneous oscillation (CHO) detection method. We implemented these criteria based on an autocorrelation approach to determine an oscillation's fundamental frequency. We evaluated CHO by verifying its performance on simulated non-sinusoidal oscillatory bursts and validated its ability to determine the fundamental frequency of neural oscillations in electrocorticographic (ECoG), electroencephalographic (EEG), and stereoelectroencephalographic (SEEG) signals recorded from 27 human subjects. Our results demonstrate that CHO outperforms conventional techniques in accurately detecting oscillations. In summary, CHO demonstrates high precision and specificity in detecting neural oscillations in time and frequency domains. The method's specificity enables the detailed study of non-sinusoidal characteristics of oscillations, such as the degree of asymmetry and waveform of an oscillation. Furthermore, CHO can be applied to identify how neural oscillations govern interactions throughout the brain and to determine oscillatory biomarkers that index abnormal brain function.&lt;/p&gt;</style></abstract></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Nourmohammadi, Amin</style></author><author><style face="normal" font="default" size="100%">Swift, James R</style></author><author><style face="normal" font="default" size="100%">de Pesters, Adriana</style></author><author><style face="normal" font="default" size="100%">Guay, Christian S</style></author><author><style face="normal" font="default" size="100%">Adamo, Matthew A</style></author><author><style face="normal" font="default" size="100%">Dalfino, John C</style></author><author><style face="normal" font="default" size="100%">Ritaccio, Anthony L</style></author><author><style face="normal" font="default" size="100%">Schalk, Gerwin</style></author><author><style face="normal" font="default" size="100%">Brunner, Peter</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Passive functional mapping of receptive language cortex during general anesthesia using electrocorticography.</style></title><secondary-title><style face="normal" font="default" size="100%">Clin Neurophysiol</style></secondary-title><alt-title><style face="normal" font="default" size="100%">Clin Neurophysiol</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Anesthesia, General</style></keyword><keyword><style  face="normal" font="default" size="100%">Brain</style></keyword><keyword><style  face="normal" font="default" size="100%">Brain Mapping</style></keyword><keyword><style  face="normal" font="default" size="100%">Cerebral Cortex</style></keyword><keyword><style  face="normal" font="default" size="100%">Electrocorticography</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Language</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2023</style></year><pub-dates><date><style  face="normal" font="default" size="100%">03/2023</style></date></pub-dates></dates><volume><style face="normal" font="default" size="100%">147</style></volume><pages><style face="normal" font="default" size="100%">31-44</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;&lt;b&gt;OBJECTIVE: &lt;/b&gt;To investigate the feasibility of passive functional mapping in the receptive language cortex during general anesthesia using electrocorticographic (ECoG) signals.&lt;/p&gt;&lt;p&gt;&lt;b&gt;METHODS: &lt;/b&gt;We used subdurally placed ECoG grids to record cortical responses to speech stimuli during awake and anesthesia conditions. We identified the cortical areas with significant responses to the stimuli using the spectro-temporal consistency of the brain signal in the broadband gamma (BBG) frequency band (70-170 Hz).&lt;/p&gt;&lt;p&gt;&lt;b&gt;RESULTS: &lt;/b&gt;We found that ECoG BBG responses during general anesthesia effectively identify cortical regions associated with receptive language function. Our analyses demonstrated that the ability to identify receptive language cortex varies across different states and depths of anesthesia. We confirmed these results by comparing them to receptive language areas identified during the awake condition. Quantification of these results demonstrated an average sensitivity and specificity of passive language mapping during general anesthesia to be 49±7.7% and 100%, respectively.&lt;/p&gt;&lt;p&gt;&lt;b&gt;CONCLUSION: &lt;/b&gt;Our results demonstrate that mapping receptive language cortex in patients during general anesthesia is feasible.&lt;/p&gt;&lt;p&gt;&lt;b&gt;SIGNIFICANCE: &lt;/b&gt;Our proposed protocol could greatly expand the population of patients that can benefit from passive language mapping techniques, and could eliminate the risks associated with electrocortical stimulation during an awake craniotomy.&lt;/p&gt;</style></abstract></record></records></xml>