<?xml version="1.0" encoding="UTF-8"?><xml><records><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Blenkmann, Alejandro Omar</style></author><author><style face="normal" font="default" size="100%">Leske, Sabine Liliana</style></author><author><style face="normal" font="default" size="100%">Llorens, Anaïs</style></author><author><style face="normal" font="default" size="100%">Lin, Jack J</style></author><author><style face="normal" font="default" size="100%">Chang, Edward F</style></author><author><style face="normal" font="default" size="100%">Brunner, Peter</style></author><author><style face="normal" font="default" size="100%">Schalk, Gerwin</style></author><author><style face="normal" font="default" size="100%">Ivanovic, Jugoslav</style></author><author><style face="normal" font="default" size="100%">Larsson, Pål Gunnar</style></author><author><style face="normal" font="default" size="100%">Knight, Robert Thomas</style></author><author><style face="normal" font="default" size="100%">Endestad, Tor</style></author><author><style face="normal" font="default" size="100%">Solbakk, Anne-Kristin</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Anatomical registration of intracranial electrodes. Robust model-based localization and deformable smooth brain-shift compensation methods.</style></title><secondary-title><style face="normal" font="default" size="100%">J Neurosci Methods</style></secondary-title><alt-title><style face="normal" font="default" size="100%">J Neurosci Methods</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Brain</style></keyword><keyword><style  face="normal" font="default" size="100%">Cerebral Cortex</style></keyword><keyword><style  face="normal" font="default" size="100%">Electrodes</style></keyword><keyword><style  face="normal" font="default" size="100%">Electrodes, Implanted</style></keyword><keyword><style  face="normal" font="default" size="100%">Electroencephalography</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Magnetic Resonance Imaging</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2024</style></year><pub-dates><date><style  face="normal" font="default" size="100%">2024 Apr</style></date></pub-dates></dates><volume><style face="normal" font="default" size="100%">404</style></volume><pages><style face="normal" font="default" size="100%">110056</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;&lt;b&gt;BACKGROUND: &lt;/b&gt;Intracranial electrodes are typically localized from post-implantation CT artifacts. Automatic algorithms localizing low signal-to-noise ratio artifacts and high-density electrode arrays are missing. Additionally, implantation of grids/strips introduces brain deformations, resulting in registration errors when fusing post-implantation CT and pre-implantation MR images. Brain-shift compensation methods project electrode coordinates to cortex, but either fail to produce smooth solutions or do not account for brain deformations.&lt;/p&gt;&lt;p&gt;&lt;b&gt;NEW METHODS: &lt;/b&gt;We first introduce GridFit, a model-based fitting approach that simultaneously localizes all electrodes' CT artifacts in grids, strips, or depth arrays. Second, we present CEPA, a brain-shift compensation algorithm combining orthogonal-based projections, spring-mesh models, and spatial regularization constraints.&lt;/p&gt;&lt;p&gt;&lt;b&gt;RESULTS: &lt;/b&gt;We tested GridFit on ∼6000 simulated scenarios. The localization of CT artifacts showed robust performance under difficult scenarios, such as noise, overlaps, and high-density implants (&lt;1 mm errors). Validation with data from 20 challenging patients showed 99% accurate localization of the electrodes (3160/3192). We tested CEPA brain-shift compensation with data from 15 patients. Projections accounted for simple mechanical deformation principles with &lt; 0.4 mm errors. The inter-electrode distances smoothly changed across neighbor electrodes, while changes in inter-electrode distances linearly increased with projection distance.&lt;/p&gt;&lt;p&gt;&lt;b&gt;COMPARISON WITH EXISTING METHODS: &lt;/b&gt;GridFit succeeded in difficult scenarios that challenged available methods and outperformed visual localization by preserving the inter-electrode distance. CEPA registration errors were smaller than those obtained for well-established alternatives. Additionally, modeling resting-state high-frequency activity in five patients further supported CEPA.&lt;/p&gt;&lt;p&gt;&lt;b&gt;CONCLUSION: &lt;/b&gt;GridFit and CEPA are versatile tools for registering intracranial electrode coordinates, providing highly accurate results even in the most challenging implantation scenarios. The methods are implemented in the iElectrodes open-source toolbox.&lt;/p&gt;</style></abstract></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Li, Guangye</style></author><author><style face="normal" font="default" size="100%">Jiang, Shize</style></author><author><style face="normal" font="default" size="100%">Chen, Chen</style></author><author><style face="normal" font="default" size="100%">Peter Brunner</style></author><author><style face="normal" font="default" size="100%">Wu, Zehan</style></author><author><style face="normal" font="default" size="100%">Schalk, Gerwin</style></author><author><style face="normal" font="default" size="100%">Chen, Liang</style></author><author><style face="normal" font="default" size="100%">Zhang, Dingguo</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">iEEGview: an open-source multifunction GUI-based Matlab toolbox for localization and visualization of human intracranial electrodes.</style></title><secondary-title><style face="normal" font="default" size="100%">J Neural Eng</style></secondary-title><alt-title><style face="normal" font="default" size="100%">J Neural Eng</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Brain</style></keyword><keyword><style  face="normal" font="default" size="100%">Brain Mapping</style></keyword><keyword><style  face="normal" font="default" size="100%">Electrocorticography</style></keyword><keyword><style  face="normal" font="default" size="100%">Electrodes, Implanted</style></keyword><keyword><style  face="normal" font="default" size="100%">Electroencephalography</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Magnetic Resonance Imaging</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2019</style></year><pub-dates><date><style  face="normal" font="default" size="100%">12/2019</style></date></pub-dates></dates><volume><style face="normal" font="default" size="100%">17</style></volume><pages><style face="normal" font="default" size="100%">016016</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;&lt;b&gt;OBJECTIVE: &lt;/b&gt;The precise localization of intracranial electrodes is a fundamental step relevant to the analysis of intracranial electroencephalography (iEEG) recordings in various fields. With the increasing development of iEEG studies in human neuroscience, higher requirements have been posed on the localization process, resulting in urgent demand for more integrated, easy-operation and versatile tools for electrode localization and visualization. With the aim of addressing this need, we develop an easy-to-use and multifunction toolbox called iEEGview, which can be used for the localization and visualization of human intracranial electrodes.&lt;/p&gt;&lt;p&gt;&lt;b&gt;APPROACH: &lt;/b&gt;iEEGview is written in Matlab scripts and implemented with a GUI. From the GUI, by taking only pre-implant MRI and post-implant CT images as input, users can directly run the full localization pipeline including brain segmentation, image co-registration, electrode reconstruction, anatomical information identification, activation map generation and electrode projection from native brain space into common brain space for group analysis. Additionally, iEEGview implements methods for brain shift correction, visual location inspection on MRI slices and computation of certainty index in anatomical label assignment.&lt;/p&gt;&lt;p&gt;&lt;b&gt;MAIN RESULTS: &lt;/b&gt;All the introduced functions of iEEGview work reliably and successfully, and are tested by images from 28 human subjects implanted with depth and/or subdural electrodes.&lt;/p&gt;&lt;p&gt;&lt;b&gt;SIGNIFICANCE: &lt;/b&gt;iEEGview is the first public Matlab GUI-based software for intracranial electrode localization and visualization that holds integrated capabilities together within one pipeline. iEEGview promotes convenience and efficiency for the localization process, provides rich localization information for further analysis and offers solutions for addressing raised technical challenges. Therefore, it can serve as a useful tool in facilitating iEEG studies.&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">1</style></issue></record></records></xml>