<?xml version="1.0" encoding="UTF-8"?><xml><records><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Adam J Wilson</style></author><author><style face="normal" font="default" size="100%">Mellinger, Jürgen</style></author><author><style face="normal" font="default" size="100%">Gerwin Schalk</style></author><author><style face="normal" font="default" size="100%">Williams, Justin C</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">A procedure for measuring latencies in brain-computer interfaces.</style></title><secondary-title><style face="normal" font="default" size="100%">IEEE Trans Biomed Eng</style></secondary-title><alt-title><style face="normal" font="default" size="100%">IEEE Trans Biomed Eng</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Brain</style></keyword><keyword><style  face="normal" font="default" size="100%">Computer Systems</style></keyword><keyword><style  face="normal" font="default" size="100%">Electroencephalography</style></keyword><keyword><style  face="normal" font="default" size="100%">Evoked Potentials</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Models, Neurological</style></keyword><keyword><style  face="normal" font="default" size="100%">Reproducibility of Results</style></keyword><keyword><style  face="normal" font="default" size="100%">Signal Processing, Computer-Assisted</style></keyword><keyword><style  face="normal" font="default" size="100%">Time Factors</style></keyword><keyword><style  face="normal" font="default" size="100%">User-Computer Interface</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2010</style></year><pub-dates><date><style  face="normal" font="default" size="100%">06/2010</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/20403781</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">57</style></volume><pages><style face="normal" font="default" size="100%">1785-97</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;Brain-computer interface (BCI) systems must process neural signals with consistent timing in order to support adequate system performance. Thus, it is important to have the capability to determine whether a particular BCI configuration (i.e., hardware and software) provides adequate timing performance for a particular experiment. This report presents a method of measuring and quantifying different aspects of system timing in several typical BCI experiments across a range of settings, and presents comprehensive measures of expected overall system latency for each experimental configuration.&lt;/span&gt;&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">7</style></issue></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>10</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Miller, John W</style></author><author><style face="normal" font="default" size="100%">Hermes, Dora</style></author><author><style face="normal" font="default" size="100%">Gerwin Schalk</style></author><author><style face="normal" font="default" size="100%">Ramsey, Nick F</style></author><author><style face="normal" font="default" size="100%">Jagadeesh, Bharathi</style></author><author><style face="normal" font="default" size="100%">den Nijs, Marcel</style></author><author><style face="normal" font="default" size="100%">Ojemann, J G</style></author><author><style face="normal" font="default" size="100%">Rao, Rajesh P N</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Detection of spontaneous class-specific visual stimuli with high temporal accuracy in human electrocorticography.</style></title><secondary-title><style face="normal" font="default" size="100%">Conf Proc IEEE Eng Med Biol Soc</style></secondary-title><alt-title><style face="normal" font="default" size="100%">Conf Proc IEEE Eng Med Biol Soc</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Algorithms</style></keyword><keyword><style  face="normal" font="default" size="100%">Electrocardiography</style></keyword><keyword><style  face="normal" font="default" size="100%">Evoked Potentials, Visual</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Male</style></keyword><keyword><style  face="normal" font="default" size="100%">Pattern Recognition, Automated</style></keyword><keyword><style  face="normal" font="default" size="100%">Pattern Recognition, Visual</style></keyword><keyword><style  face="normal" font="default" size="100%">Photic Stimulation</style></keyword><keyword><style  face="normal" font="default" size="100%">Reproducibility of Results</style></keyword><keyword><style  face="normal" font="default" size="100%">Sensitivity and Specificity</style></keyword><keyword><style  face="normal" font="default" size="100%">User-Computer Interface</style></keyword><keyword><style  face="normal" font="default" size="100%">Visual Cortex</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2009</style></year><pub-dates><date><style  face="normal" font="default" size="100%">2009</style></date></pub-dates></dates><volume><style face="normal" font="default" size="100%">2009</style></volume><pages><style face="normal" font="default" size="100%">6465-8</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">Most brain-computer interface classification experiments from electrical potential recordings have been focused on the identification of classes of stimuli or behavior where the timing of experimental parameters is known or pre-designated. Real world experience, however, is spontaneous, and to this end we describe an experiment predicting the occurrence, timing, and types of visual stimuli perceived by a human subject from electrocorticographic recordings. All 300 of 300 presented stimuli were correctly detected, with a temporal precision of order 20 ms. The type of stimulus (face/house) was correctly identified in 95% of these cases. There were approximately 20 false alarm events, corresponding to a late 2nd neuronal response to a previously identified event.</style></abstract></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>10</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Gerwin Schalk</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Effective brain-computer interfacing using BCI2000.</style></title><secondary-title><style face="normal" font="default" size="100%">Conf Proc IEEE Eng Med Biol Soc</style></secondary-title><alt-title><style face="normal" font="default" size="100%">Conf Proc IEEE Eng Med Biol Soc</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Algorithms</style></keyword><keyword><style  face="normal" font="default" size="100%">Brain</style></keyword><keyword><style  face="normal" font="default" size="100%">Electrocardiography</style></keyword><keyword><style  face="normal" font="default" size="100%">Equipment Design</style></keyword><keyword><style  face="normal" font="default" size="100%">Equipment Failure Analysis</style></keyword><keyword><style  face="normal" font="default" size="100%">Rehabilitation</style></keyword><keyword><style  face="normal" font="default" size="100%">Reproducibility of Results</style></keyword><keyword><style  face="normal" font="default" size="100%">Sensitivity and Specificity</style></keyword><keyword><style  face="normal" font="default" size="100%">Signal Processing, Computer-Assisted</style></keyword><keyword><style  face="normal" font="default" size="100%">User-Computer Interface</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2009</style></year><pub-dates><date><style  face="normal" font="default" size="100%">2009</style></date></pub-dates></dates><volume><style face="normal" font="default" size="100%">2009</style></volume><pages><style face="normal" font="default" size="100%">5498-501</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">To facilitate research and development in Brain-Computer Interface (BCI) research, we have been developing a general-purpose BCI system, called BCI2000, over the past nine years. This system has enjoyed a growing adoption in BCI and related areas and has been the basis for some of the most impressive studies reported to date. This paper gives an update on the status of this project by describing the principles of the BCI2000 system, its benefits, and impact on the field to date.</style></abstract></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Gerwin Schalk</style></author><author><style face="normal" font="default" size="100%">Leuthardt, E C</style></author><author><style face="normal" font="default" size="100%">Peter Brunner</style></author><author><style face="normal" font="default" size="100%">Ojemann, J G</style></author><author><style face="normal" font="default" size="100%">Lester A Gerhardt</style></author><author><style face="normal" font="default" size="100%">Jonathan Wolpaw</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Real-time detection of event-related brain activity.</style></title><secondary-title><style face="normal" font="default" size="100%">Neuroimage</style></secondary-title><alt-title><style face="normal" font="default" size="100%">Neuroimage</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Adult</style></keyword><keyword><style  face="normal" font="default" size="100%">Algorithms</style></keyword><keyword><style  face="normal" font="default" size="100%">Brain Mapping</style></keyword><keyword><style  face="normal" font="default" size="100%">Computer Systems</style></keyword><keyword><style  face="normal" font="default" size="100%">Diagnosis, Computer-Assisted</style></keyword><keyword><style  face="normal" font="default" size="100%">Electroencephalography</style></keyword><keyword><style  face="normal" font="default" size="100%">Epilepsy</style></keyword><keyword><style  face="normal" font="default" size="100%">Evoked Potentials</style></keyword><keyword><style  face="normal" font="default" size="100%">Female</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Male</style></keyword><keyword><style  face="normal" font="default" size="100%">Pattern Recognition, Automated</style></keyword><keyword><style  face="normal" font="default" size="100%">Reproducibility of Results</style></keyword><keyword><style  face="normal" font="default" size="100%">Sensitivity and Specificity</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2008</style></year><pub-dates><date><style  face="normal" font="default" size="100%">11/2008</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/18718544</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">43</style></volume><pages><style face="normal" font="default" size="100%">245-9</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;The complexity and inter-individual variation of&amp;nbsp;&lt;/span&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;brain&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;&amp;nbsp;signals impedes real-time detection of events in raw signals. To convert these complex signals into results that can be readily understood, current approaches usually apply statistical methods to data from known conditions after all data have been collected. The capability to provide meaningful visualization of complex&amp;nbsp;&lt;/span&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;brain&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;&amp;nbsp;signals without the requirement to initially collect data from all conditions would provide a new tool, essentially a new imaging technique, that would open up new avenues for the study of&amp;nbsp;&lt;/span&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;brain&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;&amp;nbsp;function. Here we show that a new analysis approach, called SIGFRIED, can overcome this serious limitation of current methods. SIGFRIED can visualize&amp;nbsp;&lt;/span&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;brain&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;&amp;nbsp;signal changes without requiring prior data collection from all conditions. This capacity is particularly well suited to applications in which comprehensive prior data collection is impossible or impractical, such as intraoperative localization of cortical function or detection of epileptic seizures.&lt;/span&gt;&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">2</style></issue></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Benjamin Blankertz</style></author><author><style face="normal" font="default" size="100%">Müller, Klaus-Robert</style></author><author><style face="normal" font="default" size="100%">Curio, Gabriel</style></author><author><style face="normal" font="default" size="100%">Theresa M Vaughan</style></author><author><style face="normal" font="default" size="100%">Gerwin Schalk</style></author><author><style face="normal" font="default" size="100%">Jonathan Wolpaw</style></author><author><style face="normal" font="default" size="100%">Schlögl, Alois</style></author><author><style face="normal" font="default" size="100%">Neuper, Christa</style></author><author><style face="normal" font="default" size="100%">Pfurtscheller, Gert</style></author><author><style face="normal" font="default" size="100%">Hinterberger, T.</style></author><author><style face="normal" font="default" size="100%">Schröder, Michael</style></author><author><style face="normal" font="default" size="100%">Niels Birbaumer</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">The BCI Competition 2003: Progress and perspectives in detection and discrimination of EEG single trials.</style></title><secondary-title><style face="normal" font="default" size="100%">IEEE Trans Biomed Eng</style></secondary-title><alt-title><style face="normal" font="default" size="100%">IEEE Trans Biomed Eng</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Adult</style></keyword><keyword><style  face="normal" font="default" size="100%">Algorithms</style></keyword><keyword><style  face="normal" font="default" size="100%">Amyotrophic Lateral Sclerosis</style></keyword><keyword><style  face="normal" font="default" size="100%">Artificial Intelligence</style></keyword><keyword><style  face="normal" font="default" size="100%">Brain</style></keyword><keyword><style  face="normal" font="default" size="100%">Cognition</style></keyword><keyword><style  face="normal" font="default" size="100%">Databases, Factual</style></keyword><keyword><style  face="normal" font="default" size="100%">Electroencephalography</style></keyword><keyword><style  face="normal" font="default" size="100%">Evoked Potentials</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Reproducibility of Results</style></keyword><keyword><style  face="normal" font="default" size="100%">Sensitivity and Specificity</style></keyword><keyword><style  face="normal" font="default" size="100%">User-Computer Interface</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2004</style></year><pub-dates><date><style  face="normal" font="default" size="100%">06/2004</style></date></pub-dates></dates><volume><style face="normal" font="default" size="100%">51</style></volume><pages><style face="normal" font="default" size="100%">1044-51</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">Interest in developing a new method of man-to-machine communication--a brain-computer interface (BCI)--has grown steadily over the past few decades. BCIs create a new communication channel between the brain and an output device by bypassing conventional motor output pathways of nerves and muscles. These systems use signals recorded from the scalp, the surface of the cortex, or from inside the brain to enable users to control a variety of applications including simple word-processing software and orthotics. BCI technology could therefore provide a new communication and control option for individuals who cannot otherwise express their wishes to the outside world. Signal processing and classification methods are essential tools in the development of improved BCI technology. We organized the BCI Competition 2003 to evaluate the current state of the art of these tools. Four laboratories well versed in EEG-based BCI research provided six data sets in a documented format. We made these data sets (i.e., labeled training sets and unlabeled test sets) and their descriptions available on the Internet. The goal in the competition was to maximize the performance measure for the test labels. Researchers worldwide tested their algorithms and competed for the best classification results. This paper describes the six data sets and the results and function of the most successful algorithms.</style></abstract><issue><style face="normal" font="default" size="100%">6</style></issue></record></records></xml>