<?xml version="1.0" encoding="UTF-8"?><xml><records><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Vansteensel, Mariska J</style></author><author><style face="normal" font="default" size="100%">Hermes, Dora</style></author><author><style face="normal" font="default" size="100%">Aarnoutse, Erik J</style></author><author><style face="normal" font="default" size="100%">Bleichner, Martin G</style></author><author><style face="normal" font="default" size="100%">Gerwin Schalk</style></author><author><style face="normal" font="default" size="100%">van Rijen, Peter C</style></author><author><style face="normal" font="default" size="100%">Leijten, Frans S S</style></author><author><style face="normal" font="default" size="100%">Ramsey, Nick F</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Brain-computer interfacing based on cognitive control.</style></title><secondary-title><style face="normal" font="default" size="100%">Ann Neurol</style></secondary-title><alt-title><style face="normal" font="default" size="100%">Ann. Neurol.</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Cognition</style></keyword><keyword><style  face="normal" font="default" size="100%">Computers</style></keyword><keyword><style  face="normal" font="default" size="100%">Electrodes</style></keyword><keyword><style  face="normal" font="default" size="100%">Electroencephalography</style></keyword><keyword><style  face="normal" font="default" size="100%">Epilepsy</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Image Processing, Computer-Assisted</style></keyword><keyword><style  face="normal" font="default" size="100%">Magnetic Resonance Imaging</style></keyword><keyword><style  face="normal" font="default" size="100%">Neuropsychological Tests</style></keyword><keyword><style  face="normal" font="default" size="100%">Oxygen</style></keyword><keyword><style  face="normal" font="default" size="100%">Prefrontal Cortex</style></keyword><keyword><style  face="normal" font="default" size="100%">Psychomotor Performance</style></keyword><keyword><style  face="normal" font="default" size="100%">Spectrum Analysis</style></keyword><keyword><style  face="normal" font="default" size="100%">Time Factors</style></keyword><keyword><style  face="normal" font="default" size="100%">User-Computer Interface</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2010</style></year><pub-dates><date><style  face="normal" font="default" size="100%">06/2010</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/20517943</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">67</style></volume><pages><style face="normal" font="default" size="100%">809-16</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;h4 style=&quot;font-size: 13px; margin: 0px 0.25em 0px 0px; text-transform: uppercase; float: left; font-family: arial, helvetica, clean, sans-serif; line-height: 17px;&quot;&gt;OBJECTIVE:&amp;nbsp;&lt;/h4&gt;
&lt;p style=&quot;margin: 0px 0px 0.5em; font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;Brain-computer interfaces (BCIs) translate deliberate intentions and associated changes in brain activity into action, thereby offering patients with severe paralysis an alternative means of communication with and control over their environment. Such systems are not available yet, partly due to the high performance standard that is required. A major challenge in the development of implantable BCIs is to identify cortical regions and related functions that an individual can reliably and consciously manipulate. Research predominantly focuses on the sensorimotor cortex, which can be activated by imagining motor actions. However, because this region may not provide an optimal solution to all patients, other neuronal networks need to be examined. Therefore, we investigated whether the cognitive control network can be used for BCI purposes. We also determined the feasibility of using functional magnetic resonance imaging (fMRI) for noninvasive localization of the cognitive control network.&lt;/p&gt;
&lt;h4 style=&quot;font-size: 13px; margin: 0px 0.25em 0px 0px; text-transform: uppercase; float: left; font-family: arial, helvetica, clean, sans-serif; line-height: 17px;&quot;&gt;METHODS:&amp;nbsp;&lt;/h4&gt;
&lt;p style=&quot;margin: 0px 0px 0.5em; font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;Three patients with intractable epilepsy, who were temporarily implanted with subdural grid electrodes for diagnostic purposes, attempted to gain BCI control using the electrocorticographic (ECoG) signal of the left dorsolateral prefrontal cortex (DLPFC).&lt;/p&gt;
&lt;h4 style=&quot;font-size: 13px; margin: 0px 0.25em 0px 0px; text-transform: uppercase; float: left; font-family: arial, helvetica, clean, sans-serif; line-height: 17px;&quot;&gt;RESULTS:&amp;nbsp;&lt;/h4&gt;
&lt;p style=&quot;margin: 0px 0px 0.5em; font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;All subjects quickly gained accurate BCI control by modulation of gamma-power of the left DLPFC. Prelocalization of the relevant region was performed with fMRI and was confirmed using the ECoG signals obtained during mental calculation localizer tasks.&lt;/p&gt;
&lt;h4 style=&quot;font-size: 13px; margin: 0px 0.25em 0px 0px; text-transform: uppercase; float: left; font-family: arial, helvetica, clean, sans-serif; line-height: 17px;&quot;&gt;INTERPRETATION:&amp;nbsp;&lt;/h4&gt;
&lt;p style=&quot;margin: 0px 0px 0.5em; font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;The results indicate that the cognitive control network is a suitable source of signals for BCI applications. They also demonstrate the feasibility of translating understanding about cognitive networks derived from functional neuroimaging into clinical applications.&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">6</style></issue></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Wisneski, Kimberly</style></author><author><style face="normal" font="default" size="100%">Nicholas R Anderson</style></author><author><style face="normal" font="default" size="100%">Gerwin Schalk</style></author><author><style face="normal" font="default" size="100%">Smyth, Matt</style></author><author><style face="normal" font="default" size="100%">Moran, D</style></author><author><style face="normal" font="default" size="100%">Leuthardt, E C</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Unique cortical physiology associated with ipsilateral hand movements and neuroprosthetic implications.</style></title><secondary-title><style face="normal" font="default" size="100%">Stroke</style></secondary-title><alt-title><style face="normal" font="default" size="100%">Stroke</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Adolescent</style></keyword><keyword><style  face="normal" font="default" size="100%">Adult</style></keyword><keyword><style  face="normal" font="default" size="100%">Artificial Limbs</style></keyword><keyword><style  face="normal" font="default" size="100%">Bionics</style></keyword><keyword><style  face="normal" font="default" size="100%">Brain Mapping</style></keyword><keyword><style  face="normal" font="default" size="100%">Child</style></keyword><keyword><style  face="normal" font="default" size="100%">Dominance, Cerebral</style></keyword><keyword><style  face="normal" font="default" size="100%">Electroencephalography</style></keyword><keyword><style  face="normal" font="default" size="100%">Female</style></keyword><keyword><style  face="normal" font="default" size="100%">Hand</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Male</style></keyword><keyword><style  face="normal" font="default" size="100%">Middle Aged</style></keyword><keyword><style  face="normal" font="default" size="100%">Motor Cortex</style></keyword><keyword><style  face="normal" font="default" size="100%">Movement</style></keyword><keyword><style  face="normal" font="default" size="100%">Paresis</style></keyword><keyword><style  face="normal" font="default" size="100%">Prosthesis Design</style></keyword><keyword><style  face="normal" font="default" size="100%">Psychomotor Performance</style></keyword><keyword><style  face="normal" font="default" size="100%">Stroke</style></keyword><keyword><style  face="normal" font="default" size="100%">User-Computer Interface</style></keyword><keyword><style  face="normal" font="default" size="100%">Volition</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2008</style></year><pub-dates><date><style  face="normal" font="default" size="100%">12/2008</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/18927456</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">39</style></volume><pages><style face="normal" font="default" size="100%">3351-9</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;h4 style=&quot;font-size: 13px; margin: 0px 0.25em 0px 0px; text-transform: uppercase; float: left; font-family: arial, helvetica, clean, sans-serif; line-height: 17px;&quot;&gt;BACKGROUND AND PURPOSE:&amp;nbsp;&lt;/h4&gt;
&lt;p style=&quot;margin: 0px 0px 0.5em; font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;&lt;span class=&quot;highlight&quot;&gt;Brain computer interfaces&lt;/span&gt;&amp;nbsp;(BCIs) offer little direct benefit to patients with hemispheric stroke because current platforms rely on signals derived from the contralateral motor cortex (the same region injured by the stroke). For BCIs to assist hemiparetic patients, the implant must use unaffected cortex ipsilateral to the affected limb. This requires the identification of distinct electrophysiological features from the motor cortex associated with ipsilateral hand movements.&lt;/p&gt;
&lt;h4 style=&quot;font-size: 13px; margin: 0px 0.25em 0px 0px; text-transform: uppercase; float: left; font-family: arial, helvetica, clean, sans-serif; line-height: 17px;&quot;&gt;METHODS:&amp;nbsp;&lt;/h4&gt;
&lt;p style=&quot;margin: 0px 0px 0.5em; font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;In this study we studied 6 patients undergoing temporary placement of intracranial electrode arrays. Electrocorticographic (ECoG) signals were recorded while the subjects engaged in specific ipsilateral or contralateral hand motor tasks. Spectral changes were identified with regards to frequency, location, and timing.&lt;/p&gt;
&lt;h4 style=&quot;font-size: 13px; margin: 0px 0.25em 0px 0px; text-transform: uppercase; float: left; font-family: arial, helvetica, clean, sans-serif; line-height: 17px;&quot;&gt;RESULTS:&amp;nbsp;&lt;/h4&gt;
&lt;p style=&quot;margin: 0px 0px 0.5em; font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;Ipsilateral hand movements were associated with electrophysiological changes that occur in lower frequency spectra, at distinct anatomic locations, and earlier than changes associated with contralateral hand movements. In a subset of 3 patients, features specific to ipsilateral and contralateral hand movements were used to control a cursor on a screen in real time. In ipsilateral derived control this was optimal with lower frequency spectra.&lt;/p&gt;
&lt;h4 style=&quot;font-size: 13px; margin: 0px 0.25em 0px 0px; text-transform: uppercase; float: left; font-family: arial, helvetica, clean, sans-serif; line-height: 17px;&quot;&gt;CONCLUSIONS:&amp;nbsp;&lt;/h4&gt;
&lt;p style=&quot;margin: 0px 0px 0.5em; font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;There are distinctive cortical electrophysiological features associated with ipsilateral movements which can be used for device control. These findings have implications for patients with hemispheric stroke because they offer a potential methodology for which a single hemisphere can be used to enhance the function of a stroke induced hemiparesis.&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">12</style></issue></record></records></xml>