<?xml version="1.0" encoding="UTF-8"?><xml><records><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">McCane, Lynn M</style></author><author><style face="normal" font="default" size="100%">Sellers, Eric W</style></author><author><style face="normal" font="default" size="100%">Dennis J. McFarland</style></author><author><style face="normal" font="default" size="100%">Mak, Joseph N</style></author><author><style face="normal" font="default" size="100%">Carmack, C Steve</style></author><author><style face="normal" font="default" size="100%">Zeitlin, Debra</style></author><author><style face="normal" font="default" size="100%">Jonathan Wolpaw</style></author><author><style face="normal" font="default" size="100%">Theresa M Vaughan</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Brain-computer interface (BCI) evaluation in people with amyotrophic lateral sclerosis.</style></title><secondary-title><style face="normal" font="default" size="100%">Amyotroph Lateral Scler Frontotemporal Degener</style></secondary-title><alt-title><style face="normal" font="default" size="100%">Amyotroph Lateral Scler Frontotemporal Degener</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Adult</style></keyword><keyword><style  face="normal" font="default" size="100%">Aged</style></keyword><keyword><style  face="normal" font="default" size="100%">Amyotrophic Lateral Sclerosis</style></keyword><keyword><style  face="normal" font="default" size="100%">Biofeedback, Psychology</style></keyword><keyword><style  face="normal" font="default" size="100%">brain-computer interfaces</style></keyword><keyword><style  face="normal" font="default" size="100%">Communication Disorders</style></keyword><keyword><style  face="normal" font="default" size="100%">Electroencephalography</style></keyword><keyword><style  face="normal" font="default" size="100%">Event-Related Potentials, P300</style></keyword><keyword><style  face="normal" font="default" size="100%">Female</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Male</style></keyword><keyword><style  face="normal" font="default" size="100%">Middle Aged</style></keyword><keyword><style  face="normal" font="default" size="100%">Online Systems</style></keyword><keyword><style  face="normal" font="default" size="100%">Photic Stimulation</style></keyword><keyword><style  face="normal" font="default" size="100%">Psychomotor Performance</style></keyword><keyword><style  face="normal" font="default" size="100%">Reaction Time</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2014</style></year><pub-dates><date><style  face="normal" font="default" size="100%">06/2014</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/24555843</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">15</style></volume><pages><style face="normal" font="default" size="100%">207-15</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">Brain-computer interfaces (BCIs) might restore communication to people severely disabled by amyotrophic lateral sclerosis (ALS) or other disorders. We sought to: 1) define a protocol for determining whether a person with ALS can use a visual P300-based BCI; 2) determine what proportion of this population can use the BCI; and 3) identify factors affecting BCI performance. Twenty-five individuals with ALS completed an evaluation protocol using a standard 6 × 6 matrix and parameters selected by stepwise linear discrimination. With an 8-channel EEG montage, the subjects fell into two groups in BCI accuracy (chance accuracy 3%). Seventeen averaged 92 (± 3)% (range 71-100%), which is adequate for communication (G70 group). Eight averaged 12 (± 6)% (range 0-36%), inadequate for communication (L40 subject group). Performance did not correlate with disability: 11/17 (65%) of G70 subjects were severely disabled (i.e. ALSFRS-R &lt; 5). All L40 subjects had visual impairments (e.g. nystagmus, diplopia, ptosis). P300 was larger and more anterior in G70 subjects. A 16-channel montage did not significantly improve accuracy. In conclusion, most people severely disabled by ALS could use a visual P300-based BCI for communication. In those who could not, visual impairment was the principal obstacle. For these individuals, auditory P300-based BCIs might be effective.</style></abstract><issue><style face="normal" font="default" size="100%">3-4</style></issue></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Sellers, Eric W.</style></author><author><style face="normal" font="default" size="100%">Krusienski, Dean J.</style></author><author><style face="normal" font="default" size="100%">Dennis J. McFarland</style></author><author><style face="normal" font="default" size="100%">Theresa M Vaughan</style></author><author><style face="normal" font="default" size="100%">Jonathan Wolpaw</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">A P300 event-related potential brain-computer interface (BCI): the effects of matrix size and inter stimulus interval on performance.</style></title><secondary-title><style face="normal" font="default" size="100%">Biological psychology</style></secondary-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Amyotrophic Lateral Sclerosis</style></keyword><keyword><style  face="normal" font="default" size="100%">brain-computer interface</style></keyword><keyword><style  face="normal" font="default" size="100%">electroencephalogram</style></keyword><keyword><style  face="normal" font="default" size="100%">event-related potentials</style></keyword><keyword><style  face="normal" font="default" size="100%">P300</style></keyword><keyword><style  face="normal" font="default" size="100%">Rehabilitation</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2006</style></year><pub-dates><date><style  face="normal" font="default" size="100%">10/2006</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/16860920</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">73</style></volume><pages><style face="normal" font="default" size="100%">242–252</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">We describe a study designed to assess properties of a P300 brain-computer interface (BCI). The BCI presents the user with a matrix containing letters and numbers. The user attends to a character to be communicated and the rows and columns of the matrix briefly intensify. Each time the attended character is intensified it serves as a rare event in an oddball sequence and it elicits a P300 response. The BCI works by detecting which character elicited a P300 response. We manipulated the size of the character matrix (either 3 x 3 or 6 x 6) and the duration of the inter stimulus interval (ISI) between intensifications (either 175 or 350 ms). Online accuracy was highest for the 3 x 3 matrix 175-ms ISI condition, while bit rate was highest for the 6 x 6 matrix 175-ms ISI condition. Average accuracy in the best condition for each subject was 88%. P300 amplitude was significantly greater for the attended stimulus and for the 6 x 6 matrix. This work demonstrates that matrix size and ISI are important variables to consider when optimizing a BCI system for individual users and that a P300-BCI can be used for effective communication.</style></abstract></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Kübler, A.</style></author><author><style face="normal" font="default" size="100%">Nijboer, F</style></author><author><style face="normal" font="default" size="100%">Mellinger, Jürgen</style></author><author><style face="normal" font="default" size="100%">Theresa M Vaughan</style></author><author><style face="normal" font="default" size="100%">Pawelzik, H</style></author><author><style face="normal" font="default" size="100%">Gerwin Schalk</style></author><author><style face="normal" font="default" size="100%">Dennis J. McFarland</style></author><author><style face="normal" font="default" size="100%">Niels Birbaumer</style></author><author><style face="normal" font="default" size="100%">Jonathan Wolpaw</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Patients with ALS can use sensorimotor rhythms to operate a brain-computer interface.</style></title><secondary-title><style face="normal" font="default" size="100%">Neurology</style></secondary-title><alt-title><style face="normal" font="default" size="100%">Neurology</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Aged</style></keyword><keyword><style  face="normal" font="default" size="100%">Amyotrophic Lateral Sclerosis</style></keyword><keyword><style  face="normal" font="default" size="100%">Electroencephalography</style></keyword><keyword><style  face="normal" font="default" size="100%">Evoked Potentials, Motor</style></keyword><keyword><style  face="normal" font="default" size="100%">Evoked Potentials, Somatosensory</style></keyword><keyword><style  face="normal" font="default" size="100%">Female</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Imagination</style></keyword><keyword><style  face="normal" font="default" size="100%">Male</style></keyword><keyword><style  face="normal" font="default" size="100%">Middle Aged</style></keyword><keyword><style  face="normal" font="default" size="100%">Motor Cortex</style></keyword><keyword><style  face="normal" font="default" size="100%">Movement</style></keyword><keyword><style  face="normal" font="default" size="100%">Paralysis</style></keyword><keyword><style  face="normal" font="default" size="100%">Photic Stimulation</style></keyword><keyword><style  face="normal" font="default" size="100%">Prostheses and Implants</style></keyword><keyword><style  face="normal" font="default" size="100%">Somatosensory Cortex</style></keyword><keyword><style  face="normal" font="default" size="100%">Treatment Outcome</style></keyword><keyword><style  face="normal" font="default" size="100%">User-Computer Interface</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2005</style></year><pub-dates><date><style  face="normal" font="default" size="100%">05/2005</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/15911809</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">64</style></volume><pages><style face="normal" font="default" size="100%">1775-7</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;People with severe motor disabilities can maintain an acceptable quality of life if they can communicate.&amp;nbsp;&lt;/span&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;Brain-computer interfaces&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;&amp;nbsp;(BCIs), which do not depend on muscle control, can provide communication. Four people severely disabled by ALS learned to operate a BCI with EEG rhythms recorded over sensorimotor cortex. These results suggest that a sensorimotor rhythm-&lt;/span&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;based&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;&amp;nbsp;BCI could help maintain quality of life for people with ALS.&lt;/span&gt;&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">10</style></issue></record></records></xml>