<?xml version="1.0" encoding="UTF-8"?><xml><records><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Li, Guangye</style></author><author><style face="normal" font="default" size="100%">Jiang, Shize</style></author><author><style face="normal" font="default" size="100%">Chen, Chen</style></author><author><style face="normal" font="default" size="100%">Peter Brunner</style></author><author><style face="normal" font="default" size="100%">Wu, Zehan</style></author><author><style face="normal" font="default" size="100%">Schalk, Gerwin</style></author><author><style face="normal" font="default" size="100%">Chen, Liang</style></author><author><style face="normal" font="default" size="100%">Zhang, Dingguo</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">iEEGview: an open-source multifunction GUI-based Matlab toolbox for localization and visualization of human intracranial electrodes.</style></title><secondary-title><style face="normal" font="default" size="100%">J Neural Eng</style></secondary-title><alt-title><style face="normal" font="default" size="100%">J Neural Eng</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Brain</style></keyword><keyword><style  face="normal" font="default" size="100%">Brain Mapping</style></keyword><keyword><style  face="normal" font="default" size="100%">Electrocorticography</style></keyword><keyword><style  face="normal" font="default" size="100%">Electrodes, Implanted</style></keyword><keyword><style  face="normal" font="default" size="100%">Electroencephalography</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Magnetic Resonance Imaging</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2019</style></year><pub-dates><date><style  face="normal" font="default" size="100%">12/2019</style></date></pub-dates></dates><volume><style face="normal" font="default" size="100%">17</style></volume><pages><style face="normal" font="default" size="100%">016016</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;&lt;b&gt;OBJECTIVE: &lt;/b&gt;The precise localization of intracranial electrodes is a fundamental step relevant to the analysis of intracranial electroencephalography (iEEG) recordings in various fields. With the increasing development of iEEG studies in human neuroscience, higher requirements have been posed on the localization process, resulting in urgent demand for more integrated, easy-operation and versatile tools for electrode localization and visualization. With the aim of addressing this need, we develop an easy-to-use and multifunction toolbox called iEEGview, which can be used for the localization and visualization of human intracranial electrodes.&lt;/p&gt;&lt;p&gt;&lt;b&gt;APPROACH: &lt;/b&gt;iEEGview is written in Matlab scripts and implemented with a GUI. From the GUI, by taking only pre-implant MRI and post-implant CT images as input, users can directly run the full localization pipeline including brain segmentation, image co-registration, electrode reconstruction, anatomical information identification, activation map generation and electrode projection from native brain space into common brain space for group analysis. Additionally, iEEGview implements methods for brain shift correction, visual location inspection on MRI slices and computation of certainty index in anatomical label assignment.&lt;/p&gt;&lt;p&gt;&lt;b&gt;MAIN RESULTS: &lt;/b&gt;All the introduced functions of iEEGview work reliably and successfully, and are tested by images from 28 human subjects implanted with depth and/or subdural electrodes.&lt;/p&gt;&lt;p&gt;&lt;b&gt;SIGNIFICANCE: &lt;/b&gt;iEEGview is the first public Matlab GUI-based software for intracranial electrode localization and visualization that holds integrated capabilities together within one pipeline. iEEGview promotes convenience and efficiency for the localization process, provides rich localization information for further analysis and offers solutions for addressing raised technical challenges. Therefore, it can serve as a useful tool in facilitating iEEG studies.&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">1</style></issue></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Peter Brunner</style></author><author><style face="normal" font="default" size="100%">A L Ritaccio</style></author><author><style face="normal" font="default" size="100%">Lynch, Timothy M</style></author><author><style face="normal" font="default" size="100%">Emrich, Joseph F</style></author><author><style face="normal" font="default" size="100%">Adam J Wilson</style></author><author><style face="normal" font="default" size="100%">Williams, Justin C</style></author><author><style face="normal" font="default" size="100%">Aarnoutse, Erik J</style></author><author><style face="normal" font="default" size="100%">Ramsey, Nick F</style></author><author><style face="normal" font="default" size="100%">Leuthardt, E C</style></author><author><style face="normal" font="default" size="100%">H Bischof</style></author><author><style face="normal" font="default" size="100%">Gerwin Schalk</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">A practical procedure for real-time functional mapping of eloquent cortex using electrocorticographic signals in humans.</style></title><secondary-title><style face="normal" font="default" size="100%">Epilepsy Behav</style></secondary-title><alt-title><style face="normal" font="default" size="100%">Epilepsy Behav</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Adult</style></keyword><keyword><style  face="normal" font="default" size="100%">Brain Mapping</style></keyword><keyword><style  face="normal" font="default" size="100%">Cerebral Cortex</style></keyword><keyword><style  face="normal" font="default" size="100%">Electric Stimulation</style></keyword><keyword><style  face="normal" font="default" size="100%">Electrodes, Implanted</style></keyword><keyword><style  face="normal" font="default" size="100%">Electroencephalography</style></keyword><keyword><style  face="normal" font="default" size="100%">Epilepsy</style></keyword><keyword><style  face="normal" font="default" size="100%">Female</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Male</style></keyword><keyword><style  face="normal" font="default" size="100%">Middle Aged</style></keyword><keyword><style  face="normal" font="default" size="100%">Practice Guidelines as Topic</style></keyword><keyword><style  face="normal" font="default" size="100%">Signal Processing, Computer-Assisted</style></keyword><keyword><style  face="normal" font="default" size="100%">Young Adult</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2009</style></year><pub-dates><date><style  face="normal" font="default" size="100%">07/2009</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/19366638</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">15</style></volume><pages><style face="normal" font="default" size="100%">278-86</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;Functional mapping of eloquent cortex is often necessary prior to invasive brain surgery, but current techniques that derive this mapping have important limitations. In this article, we demonstrate the first comprehensive evaluation of a rapid, robust, and practical mapping system that uses passive recordings of electrocorticographic signals. This mapping procedure is based on the BCI2000 and SIGFRIED technologies that we have been developing over the past several years. In our study, we evaluated 10 patients with epilepsy from four different institutions and compared the results of our procedure with the results derived using electrical cortical stimulation (ECS) mapping. The results show that our procedure derives a functional motor cortical map in only a few minutes. They also show a substantial concurrence with the results derived using ECS mapping. Specifically, compared with ECS maps, a next-neighbor evaluation showed no false negatives, and only 0.46 and 1.10% false positives for hand and tongue maps, respectively. In summary, we demonstrate the first comprehensive evaluation of a practical and robust mapping procedure that could become a new tool for planning of invasive brain surgeries.&lt;/span&gt;&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">3</style></issue></record></records></xml>