<?xml version="1.0" encoding="UTF-8"?><xml><records><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Asano, Y</style></author><author><style face="normal" font="default" size="100%">Davidenko, J M</style></author><author><style face="normal" font="default" size="100%">Baxter, Bill</style></author><author><style face="normal" font="default" size="100%">Gray, R A</style></author><author><style face="normal" font="default" size="100%">Jalife, J</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Optical mapping of drug-induced polymorphic arrhythmias and torsade de pointes in the isolated rabbit heart.</style></title><secondary-title><style face="normal" font="default" size="100%">J Am Coll Cardiol</style></secondary-title><alt-title><style face="normal" font="default" size="100%">J. Am. Coll. Cardiol.</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Action Potentials</style></keyword><keyword><style  face="normal" font="default" size="100%">Animals</style></keyword><keyword><style  face="normal" font="default" size="100%">Anti-Arrhythmia Agents</style></keyword><keyword><style  face="normal" font="default" size="100%">Arrhythmias, Cardiac</style></keyword><keyword><style  face="normal" font="default" size="100%">Electrocardiography</style></keyword><keyword><style  face="normal" font="default" size="100%">Heart</style></keyword><keyword><style  face="normal" font="default" size="100%">Heart Conduction System</style></keyword><keyword><style  face="normal" font="default" size="100%">Image Processing, Computer-Assisted</style></keyword><keyword><style  face="normal" font="default" size="100%">Models, Cardiovascular</style></keyword><keyword><style  face="normal" font="default" size="100%">Organ Culture Techniques</style></keyword><keyword><style  face="normal" font="default" size="100%">Perfusion</style></keyword><keyword><style  face="normal" font="default" size="100%">Piperidines</style></keyword><keyword><style  face="normal" font="default" size="100%">Pyridines</style></keyword><keyword><style  face="normal" font="default" size="100%">Quinidine</style></keyword><keyword><style  face="normal" font="default" size="100%">Rabbits</style></keyword><keyword><style  face="normal" font="default" size="100%">Torsades de Pointes</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">1997</style></year><pub-dates><date><style  face="normal" font="default" size="100%">03/1997</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/9091531</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">29</style></volume><pages><style face="normal" font="default" size="100%">831-42</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;h4 style=&quot;font-size: 13px; margin: 0px 0.25em 0px 0px; text-transform: uppercase; float: left; font-family: arial, helvetica, clean, sans-serif; line-height: 17px;&quot;&gt;OBJECTIVES:&amp;nbsp;&lt;/h4&gt;
&lt;p style=&quot;margin: 0px 0px 0.5em; font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;This study sought to 1) test the hypothesis that in the setting of bradycardia and drug-induced action potential prolongation, multiple foci of early afterdepolarizations (EADs) result in beat to beat changes in the origin and direction of the excitation wave front and are responsible for polymorphic arrhythmias; and 2) determine whether EADs may initiate nonstationary reentry, giving rise to the typical torsade de pointes (TDP) pattern.&lt;/p&gt;
&lt;h4 style=&quot;font-size: 13px; margin: 0px 0.25em 0px 0px; text-transform: uppercase; float: left; font-family: arial, helvetica, clean, sans-serif; line-height: 17px;&quot;&gt;BACKGROUND:&amp;nbsp;&lt;/h4&gt;
&lt;p style=&quot;margin: 0px 0px 0.5em; font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;In the past, it has been difficult to associate EADs or reentry with the undulating electrocardiographic (ECG) patterns of TDP.&lt;/p&gt;
&lt;h4 style=&quot;font-size: 13px; margin: 0px 0.25em 0px 0px; text-transform: uppercase; float: left; font-family: arial, helvetica, clean, sans-serif; line-height: 17px;&quot;&gt;METHODS:&amp;nbsp;&lt;/h4&gt;
&lt;p style=&quot;margin: 0px 0px 0.5em; font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;A voltage-sensitive dye was used for high resolution&amp;nbsp;&lt;span class=&quot;highlight&quot;&gt;video&lt;/span&gt;&amp;nbsp;&lt;span class=&quot;highlight&quot;&gt;imaging&lt;/span&gt;&amp;nbsp;of electrical waves on the&amp;nbsp;&lt;span class=&quot;highlight&quot;&gt;epicardial&lt;/span&gt;&amp;nbsp;and endocardial&amp;nbsp;&lt;span class=&quot;highlight&quot;&gt;surface&lt;/span&gt;&amp;nbsp;of the Langendorff-perfused&amp;nbsp;&lt;span class=&quot;highlight&quot;&gt;rabbit&lt;/span&gt;&amp;nbsp;&lt;span class=&quot;highlight&quot;&gt;heart&lt;/span&gt;. ECG and monophasic action potentials from the right septal region were also recorded. Bradycardia was induced by ablation of the atrioventricular node.&lt;/p&gt;
&lt;h4 style=&quot;font-size: 13px; margin: 0px 0.25em 0px 0px; text-transform: uppercase; float: left; font-family: arial, helvetica, clean, sans-serif; line-height: 17px;&quot;&gt;RESULTS:&amp;nbsp;&lt;/h4&gt;
&lt;p style=&quot;margin: 0px 0px 0.5em; font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;Perfusion of low potassium chloride Tyrode solution plus quinidine led to prolongation of the action potential and the QT interval. Eventually, EADs and triggered activity ensued, giving rise to intermittent episodes of polymorphic arrhythmia. In one experiment, triggered activity was followed by a long episode of vortex-like reentry with an ECG pattern characteristic of TDP. However, in most experiments, focal activity of varying origins and propagation patterns was observed. Triggered responses also showed varying degrees of local block. Similar results were obtained with E-4031. Burst pacing both at control conditions and in the presence of quinidine consistently led to vortex-like reentry whose ECG pattern resembled TDP. However, the cycle length of the arrhythmia with quinidine was longer than that for control ([mean +/- SEM] 194 +/- 12 vs. 132 +/- 8 ms, p &amp;lt; 0.03).&lt;/p&gt;
&lt;h4 style=&quot;font-size: 13px; margin: 0px 0.25em 0px 0px; text-transform: uppercase; float: left; font-family: arial, helvetica, clean, sans-serif; line-height: 17px;&quot;&gt;CONCLUSIONS:&amp;nbsp;&lt;/h4&gt;
&lt;p style=&quot;margin: 0px 0px 0.5em; font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;Drug-induced polymorphic ventricular arrhythmias may result from beat to beat changes in wave propagation patterns initiated by EADs or EAD-induced nonstationary reentrant activity. In contrast, burst pacing-induced polymorphic tachycardia in the presence or absence of drugs is the result of nonstationary reentrant activity.&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">4</style></issue></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Baxter, Bill</style></author><author><style face="normal" font="default" size="100%">Davidenko, J M</style></author><author><style face="normal" font="default" size="100%">Loew, L M</style></author><author><style face="normal" font="default" size="100%">Wuskell, J P</style></author><author><style face="normal" font="default" size="100%">Jalife, J</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Technical features of a CCD video camera system to record cardiac fluorescence data.</style></title><secondary-title><style face="normal" font="default" size="100%">Ann Biomed Eng</style></secondary-title><alt-title><style face="normal" font="default" size="100%">Ann Biomed Eng</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Action Potentials</style></keyword><keyword><style  face="normal" font="default" size="100%">Algorithms</style></keyword><keyword><style  face="normal" font="default" size="100%">Animals</style></keyword><keyword><style  face="normal" font="default" size="100%">Body Surface Potential Mapping</style></keyword><keyword><style  face="normal" font="default" size="100%">Calibration</style></keyword><keyword><style  face="normal" font="default" size="100%">Computer Simulation</style></keyword><keyword><style  face="normal" font="default" size="100%">Electric Conductivity</style></keyword><keyword><style  face="normal" font="default" size="100%">Fluorescent Dyes</style></keyword><keyword><style  face="normal" font="default" size="100%">Image Processing, Computer-Assisted</style></keyword><keyword><style  face="normal" font="default" size="100%">Models, Cardiovascular</style></keyword><keyword><style  face="normal" font="default" size="100%">Sheep</style></keyword><keyword><style  face="normal" font="default" size="100%">Ventricular Function</style></keyword><keyword><style  face="normal" font="default" size="100%">Video Recording</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">1997</style></year><pub-dates><date><style  face="normal" font="default" size="100%">07/1997</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/9236983</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">25</style></volume><pages><style face="normal" font="default" size="100%">713-25</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;A charge-coupled device (CCD) camera was used to acquire movies of transmembrane activity from thin slices of sheep ventricular&amp;nbsp;&lt;/span&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;epicardial&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;&amp;nbsp;muscle stained with a voltage-sensitive dye. Compared with photodiodes, CCDs have high spatial resolution, but low temporal resolution. Spatial resolution in our system ranged from 0.04 to 0.14 mm/pixel; the acquisition rate was 60, 120, or 240 frames/sec. Propagating waves were readily visualized after subtraction of a background image. The optical signal had an amplitude of 1 to 6 gray levels, with signal-to-noise ratios between 1.5 and 4.4. Because CCD cameras integrate light over the frame interval, moving objects, including propagating waves, are blurred in the resulting movies. A computer model of such an integrating&amp;nbsp;&lt;/span&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;imaging&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;&amp;nbsp;system was developed to study the effects of blur, noise, filtering, and quantization on the ability to measure conduction velocity and action potential duration (APD). The model indicated that blurring, filtering, and quantization do not affect the ability to localize wave fronts in the optical data (i.e., no systematic error in determining spatial position), but noise does increase the uncertainty of the measurements. The model also showed that the low frame rates of the CCD camera introduced a systematic error in the calculation of APD: for cutoff levels &amp;gt; 50%, the APD was erroneously long. Both noise and quantization increased the uncertainty in the APD measurements. The optical measures of conduction velocity were not significantly different from those measured simultaneously with microelectrodes. Optical APDs, however, were longer than the electrically recorded APDs. This APD error could be reduced by using the 50% cutoff level and the fastest frame rate possible.&lt;/span&gt;&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">4</style></issue></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Gray, R A</style></author><author><style face="normal" font="default" size="100%">Jalife, J</style></author><author><style face="normal" font="default" size="100%">Panfilov, A</style></author><author><style face="normal" font="default" size="100%">Baxter, Bill</style></author><author><style face="normal" font="default" size="100%">Cabo, C</style></author><author><style face="normal" font="default" size="100%">Davidenko, J M</style></author><author><style face="normal" font="default" size="100%">Pertsov, A V</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Nonstationary vortexlike reentrant activity as a mechanism of polymorphic ventricular tachycardia in the isolated rabbit heart.</style></title><secondary-title><style face="normal" font="default" size="100%">Circulation</style></secondary-title><alt-title><style face="normal" font="default" size="100%">Circulation</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Animals</style></keyword><keyword><style  face="normal" font="default" size="100%">Electrocardiography</style></keyword><keyword><style  face="normal" font="default" size="100%">Heart</style></keyword><keyword><style  face="normal" font="default" size="100%">Image Processing, Computer-Assisted</style></keyword><keyword><style  face="normal" font="default" size="100%">Models, Cardiovascular</style></keyword><keyword><style  face="normal" font="default" size="100%">Perfusion</style></keyword><keyword><style  face="normal" font="default" size="100%">Rabbits</style></keyword><keyword><style  face="normal" font="default" size="100%">Tachycardia, Ventricular</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">1995</style></year><pub-dates><date><style  face="normal" font="default" size="100%">05/1995 </style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/7729033</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">91</style></volume><pages><style face="normal" font="default" size="100%">2454-69</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;h4 style=&quot;font-size: 13px; margin: 0px 0.25em 0px 0px; text-transform: uppercase; float: left; font-family: arial, helvetica, clean, sans-serif; line-height: 17px;&quot;&gt;BACKGROUND:&amp;nbsp;&lt;/h4&gt;
&lt;p style=&quot;margin: 0px 0px 0.5em; font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;Ventricular tachycardia may result from vortexlike reentrant excitation of the myocardium. Our general hypothesis is that in the structurally normal heart, these arrhythmias are the result of one or two nonstationary three-dimensional electrical scroll waves activating the heart muscle at very high frequencies.&lt;/p&gt;
&lt;h4 style=&quot;font-size: 13px; margin: 0px 0.25em 0px 0px; text-transform: uppercase; float: left; font-family: arial, helvetica, clean, sans-serif; line-height: 17px;&quot;&gt;METHODS AND RESULTS:&amp;nbsp;&lt;/h4&gt;
&lt;p style=&quot;margin: 0px 0px 0.5em; font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;We used a combination of high-resolution video imaging, electrocardiography, and image processing in the isolated rabbit heart, together with mathematical modeling. We characterized the dynamics of changes in transmembrane potential patterns on the epicardial surface of the ventricles using optical mapping. Image processing techniques were used to identify the surface manifestation of the reentrant organizing centers, and the location of these centers was used to determine the movement of the reentrant pathway. We also used numerical simulations incorporating Fitzhugh-Nagumo kinetics and realistic heart geometry to study how stationary and nonstationary scroll waves are manifest on the epicardial surface and in the simulated ECG. We present epicardial surface manifestations (reentrant spiral waves) and ECG patterns of nonstationary reentrant activity that are consistent with those generated by scroll waves established at the right and left ventricles. We identified the organizing centers of the reentrant circuits on the epicardial surface during polymorphic tachycardia, and these centers moved during the episodes. In addition, the arrhythmias that showed the greatest movement of the reentrant centers displayed the largest changes in QRS morphology. The numerical simulations showed that stationary scroll waves give rise to monomorphic ECG signals, but nonstationary meandering scroll waves give rise to undulating ECGs characteristic of torsade de pointes.&lt;/p&gt;
&lt;h4 style=&quot;font-size: 13px; margin: 0px 0.25em 0px 0px; text-transform: uppercase; float: left; font-family: arial, helvetica, clean, sans-serif; line-height: 17px;&quot;&gt;CONCLUSIONS:&amp;nbsp;&lt;/h4&gt;
&lt;p style=&quot;margin: 0px 0px 0.5em; font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;Polymorphic ventricular tachycardia in the healthy, isolated rabbit heart is the result of either a single or paired (&quot;figure-of-eight&quot;) nonstationary scroll waves. The extent of the scroll wave movement corresponds to the degree of polymorphism in the ECG. These results are consistent with our numerical simulations that showed monomorphic ECG patterns of activity for stationary scroll waves but polymorphic patterns for scroll waves that were nonstationary.&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">9</style></issue></record></records></xml>