03596nas a2200505 4500008004100000022001400041245010700055210006900162260001200231300001300243490000700256520217800263653002502441653001502466653001002481653002502491653001802516653001602534653002002550653002402570653002702594653001302621653002202634653001102656653001102667653000902678653001602687653002902703653002302732653002302755653001802778653002202796653001702818653001502835100002202850700001802872700002902890700002402919700002002943700001802963700002302981700001903004700001903023856004803042 2011 eng d a1529-240100aNonuniform high-gamma (60-500 Hz) power changes dissociate cognitive task and anatomy in human cortex.0 aNonuniform highgamma 60500 Hz power changes dissociate cognitive c02/2011 a2091-1000 v313 a
High-gamma-band (>60 Hz) power changes in cortical electrophysiology are a reliable indicator of focal, event-related cortical activity. Despite discoveries of oscillatory subthreshold and synchronous suprathreshold activity at the cellular level, there is an increasingly popular view that high-gamma-band amplitude changes recorded from cellular ensembles are the result of asynchronous firing activity that yields wideband and uniform power increases. Others have demonstrated independence of power changes in the low- and high-gamma bands, but to date, no studies have shown evidence of any such independence above 60 Hz. Based on nonuniformities in time-frequency analyses of electrocorticographic (ECoG) signals, we hypothesized that induced high-gamma-band (60-500 Hz) power changes are more heterogeneous than currently understood. Using single-word repetition tasks in six human subjects, we showed that functional responsiveness of different ECoG high-gamma sub-bands can discriminate cognitive task (e.g., hearing, reading, speaking) and cortical locations. Power changes in these sub-bands of the high-gamma range are consistently present within single trials and have statistically different time courses within the trial structure. Moreover, when consolidated across all subjects within three task-relevant anatomic regions (sensorimotor, Broca's area, and superior temporal gyrus), these behavior- and location-dependent power changes evidenced nonuniform trends across the population. Together, the independence and nonuniformity of power changes across a broad range of frequencies suggest that a new approach to evaluating high-gamma-band cortical activity is necessary. These findings show that in addition to time and location, frequency is another fundamental dimension of high-gamma dynamics.
10aAcoustic Stimulation10aAdolescent10aAdult10aAnalysis of Variance10aBrain Mapping10aBrain Waves10aCerebral Cortex10aCognition Disorders10aElectroencephalography10aEpilepsy10aEvoked Potentials10aFemale10aHumans10aMale10aMiddle Aged10aNeuropsychological Tests10aNonlinear Dynamics10aPhotic Stimulation10aReaction Time10aSpectrum Analysis10aTime Factors10aVocabulary1 aGaona, Charles, M1 aSharma, Mohit1 aFreudenberg, Zachary, V.1 aBreshears, Jonathan1 aBundy, David, T1 aRoland, Jarod1 aBarbour, Dennis, L1 aSchalk, Gerwin1 aLeuthardt, E C uhttp://www.ncbi.nlm.nih.gov/pubmed/2130724602457nas a2200349 4500008004100000022001400041245012600055210006900181260001200250300001200262490000700274520141700281653001501698653001001713653001801723653002601741653002101767653001301788653002401801653000901825653001101834653001801845653001901863653003101882653002301913653004101936100002001977700002301997700002002020700001902040856004802059 2009 eng d a1879-278200aMapping broadband electrocorticographic recordings to two-dimensional hand trajectories in humans Motor control features.0 aMapping broadband electrocorticographic recordings to twodimensi c11/2009 a1257-700 v223 aBrain-machine interfaces (BMIs) aim to translate the motor intent of locked-in patients into neuroprosthetic control commands. Electrocorticographical (ECoG) signals provide promising neural inputs to BMIs as shown in recent studies. In this paper, we utilize a broadband spectrum above the fast gamma ranges and systematically study the role of spectral resolution, in which the broadband is partitioned, on the reconstruction of the patients' hand trajectories. Traditionally, the power of ECoG rhythms (<200-300 Hz) has been computed in short duration bins and instantaneously and linearly mapped to cursor trajectories. Neither time embedding, nor nonlinear mappings have been previously implemented in ECoG neuroprosthesis. Herein, mapping of neural modulations to goal-oriented motor behavior is achieved via linear adaptive filters with embedded memory depths and as a novelty through echo state networks (ESNs), which provide nonlinear mappings without compromising training complexity or increasing the number of model parameters, with up to 85% correlation. Reconstructed hand trajectories are analyzed through spatial, spectral and temporal sensitivities. The superiority of nonlinear mappings in the cases of low spectral resolution and abundance of interictal activity is discussed.
10aAlgorithms10aBrain10aBrain Mapping10aElectrodes, Implanted10aElectrodiagnosis10aEpilepsy10aFeasibility Studies10aHand10aHumans10aLinear Models10aMotor Activity10aNeural Networks (Computer)10aNonlinear Dynamics10aSignal Processing, Computer-Assisted1 aGunduz, Aysegul1 aSanchez, Justin, C1 aCarney, Paul, R1 aPrincipe, Jose uhttp://www.ncbi.nlm.nih.gov/pubmed/1964798102711nas a2200289 4500008004100000022001400041245017800055210006900233260001200302300001000314490000700324520179900331653001502130653001002145653002302155653002602178653001102204653001802215653002502233653002302258100001802281700002002299700001802319700001802337700001802355856004802373 2005 eng d a0167-876000aDiscussion on "Towards a quantitative characterization of functional states of the brain: from the non-linear methodology to the global linear description" by J. Wackermann.0 aDiscussion on Towards a quantitative characterization of functio c06/2005 a201-70 v563 aWackermann (1999) [Wackermann, J., 1999. Towards a quantitative characterization of functional states of the brain: from the non-linear methodology to the global linear description. Int. J. Psychophysiol. 34, 65-80] proposed Sigma-phi-Omega system for describing the global brain macro-state, in which Omega complexity was used to quantify the degree of synchrony between spatially distributed EEG processes. In this paper the effect of signal power on Omega complexity is discussed, which was not considered in Wackermann's paper (1999). Then an improved method for eliminating the effect of signal power on Omega complexity is proposed. Finally a case study on the degree of synchrony between two-channel EEG signals over different brain regions during hand motor imagery is given. The results show that the improved Omega complexity measure would characterize the true degree of synchrony among the EEG signals by eliminating the influence of signal power.
10aAlgorithms10aBrain10aDiagnostic Imaging10aFunctional Laterality10aHumans10aLinear Models10aModels, Neurological10aNonlinear Dynamics1 aPei, Xiao-Mei1 aZheng, Shi Dong1 aZhang, Ai-hua1 aDuan, Fu-jian1 aBin, Guang-yu uhttp://www.ncbi.nlm.nih.gov/pubmed/15866324